HOME   >   사업분야   >   NDT(비파괴검사)   >   Magyc

NDT(비파괴검사)

이미지입니다.

US Pulser

USPR 100 - US Pulser

​

​Model USPS-100 is an innovative instrument that marks a new era in ultrasonic NDT analysis. Ideally suited for
almost every ultrasonic application, the in​strument is designed to give the highest performance combining
excellence hardware characteristics with flexible software tools. USPS-100 is fully compatible with any type of
element transducer.

​

The main charateristics of the USPR 100 are:
- Fully Digital Instrument
- High Performance Ultrasound Pulser and A/D Converter in a single Device
- Up to 1000 V Pulser (spike/ square)
- 100 MSs / 16 bit Digital to Analog Converter
- Suitable for any ultrasound ap- plication: Thickness Gauge, Flaw Detection, C-Scan, etc.
- Data processing fully integrated into Flexible Software Tools.
- Ideal for laboratory use and for industrial 100% in-line production quality inspection.
- Standard USB 2.0 connection
- 19’’ rack kit available​

​

​

​

Features

​ APPLICATIONS

​

​● Location and size detection of hidden cracks,voids, disbondings

​● Measurements of internally corroded pipes

​● Detection of discontinuities in welds, forgings,composites, billets, axles, shafts, tanks

​● Measurement of elastic properties of materials

​● Thickness Measurement

​

ADVANTAGE

​

​​● A-Scan analysis upgradable to a full C-Scan instrument

​● Non-Destructive Testing alternative to standard tensile strength test (destructive)

​● Material analysis

​● Measurements Analysis and defect detection by the same instrument

 

SYSTEM SPECIFICATIONS

​

​

DIGITAL PULSER
Pulse Type (main bang)  Negative
Rise Time (10 to 90%, no load)  10 ns
Pulse Amplitude (no load)  20..500V, step 20V (Option: 100..1000V, step 100V)
Pulse Shape  Spike and Square (selectable)
Pulse width (square shape)  100 ns..50 μs, step 25 ns
Pulse Train  Burst of 1, 2, 4, 8, 16 pulses
(Option: Burst of 1..1000 pulses, as pulser only)
Pulse separation  100 ns..250 μs (step 25 ns)
Transducer Frequency Range 0,05-35 MHz
Tx/Rx Mode  Pulse-Echo (1 transducer), Dual and Through Transmission (2 transducers)
Maximum PRF (Pulse Repetition Rate)  Up to 1KHz ( 500 Hz with 2nd channel option)
A/D CONVERTER
Sampling Frequency (MHz)  100, 50, 25, 12,5
Data Points  256 .. 1024, step 256
Bandwidth  Dc to 35 MHz (-3dB)
Dynamic Range  > 110 dB
A/D Resolution  16 bits
High Pass Filter/Low Pass Filter  Digital
Averaging  1, 2, 4, 8 or 16 acquired data streams
Interface and communication  USB 2.0
Software  DLL & Labview Libraries
SOFTWARE OPTIONS
Thickness Gauge  SW Tool for single and multilayer thickness measurement
Flaw Detector  SW Tool for defect identification and measurement. Unlimited Gates
C-Scan  Flaw Detection SW Tool with X-Y encoder management
Material Analysis  SW Tool for Young Modulus and Poisson’ s Ratio measurement
HARDWARE OPTIONS
Additional UT channel full 2 channels instrument
Encoder inputs  2 inputs for differential incremental encoders (5 V TTL)
Digital Output  8 user controlled digital outputs
Multiplexer  Up to 16-Channel multiplexer
External Trigger Input & Output  External hardware synchronization
High Voltage Pulser  1000V pulse